Arq. bras. cardiol ; 111(2): 193-202, Aug. 2018. tab, graf
Article in English, Portuguese | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-950218

ABSTRACT

Abstract Background: Balloon post-dilatation (BPD) is often needed for optimizing transcatheter heart valve (THV) implantation, since paravalvular leak (PVL) after transcatheter aortic valve implantation is associated with poor outcome and mortality. Quantitative assessment of PVL severity before and after BPD is mandatory to properly assess PVL, thus improving implantation results and outcomes. Objective: To investigate a quantitative angiographic assessment of aortic regurgitation (AR) by videodensitometry before and after BPD. Methods: Videodensitometric-AR assessments (VD-AR) before and after BPD were analysed in 61 cases. Results: VD-AR decreased significantly from 24.0[18.0-30.5]% to 12.0[5.5-19.0]% (p < 0.001, a two-tailed p < 0.05 defined the statistical significance). The relative delta of VD-AR after BPD ranged from -100% (improvement) to +40% (deterioration) and its median value was -46.2%. The frequency of improvement, no change, and deterioration were 70% (n = 43), 25% (n = 15) and 5% (n = 3), respectively. Significant AR (VD-AR > 17%) was observed in 47 patients (77%) before and in 19 patients (31%) after BPD. Conclusions: VD-AR after THV implantation provides a quantitative assessment of post-TAVI regurgitation and can help in the decision-making process on performing BPD and in determining its efficacy.


Resumo Fundamento: A pós-dilatação com balão (PDB) é normalmente necessária para otimização do implante da válvula cardíaca transcateter (THV), uma vez que o "escape" ou leak paravalvar (PVL) após implante de valva aórtica transcateter está associada com desfecho ruim e mortalidade. A avaliação quantitativa da gravidade do PVL antes e após a PDB é mandatória para se avaliar adequadamente o PVL e, assim, melhorar os resultados e os desfechos do implante. Objetivo: Investigar uma avalição angiográfica quantitativa da regurgitação aórtica (RA) por videodensitometria (VD-RA) antes e após a PDB. Métodos: Resultados da VD-RA antes e após a PDB foram analisados em 61 casos. Resultados Houve diminuição significativa da VD-RA de 24,0(18,0-30,5)% para 12,0(5,5-19,0)% (p < 0,001; p < 0,05 bilateral foi definido como significância estatística). O delta relativo de VD-RA após a PDB variou de -100% (melhora) a +40% (piora) e o valor mediano foi -46,2%. As frequências de melhora, ausência de mudança, e piora foram 70% (n = 43), 25% (n = 15) e 5% (n = 3), respectivamente. Observou-se RA significativo (VD-RA > 17%) em 47 pacientes (77%) antes e em 19 pacientes (31%) após a PDB. Conclusões: A VD-RA após o implante de THV possibilita a avaliação quantitativa da regurgitação pós-TAVI, e pode auxiliar na tomada de decisão quanto à realização ou não da PDB, bem como na avaliação de sua eficácia.


Subject(s)
Humans , Male , Female , Aged, 80 and over , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/diagnostic imaging , Transcatheter Aortic Valve Replacement , Postoperative Complications/diagnostic imaging , Video Recording , Severity of Illness Index , Aortography , Densitometry , Transcatheter Aortic Valve Replacement/adverse effects
3.
Rev. bras. cardiol. invasiva ; 22(3): 252-257, Jul-Sep/2014. tab, graf
Article in Portuguese | LILACS-Express | LILACS, SES-SP | ID: lil-732777

ABSTRACT

Introdução: O volume de hiperplasia intimal correlaciona-se com a injúria arterial após implante de stents não farmacológicos. No entanto, pouco se sabe a respeito do impacto da injúria arterial na resposta inflamatória/proliferativa com os stents farmacológicos. Investigamos o impacto da injúria arterial, avaliada pela relação balão/artéria, no volume de obstrução neontimal, avaliado pelo ultrassom intracoronário 12 meses após o implante de stents farmacológicos com eluição de zotarolimus. Métodos: A relação balão/artéria foi definida como a razão do diâmetro máximo do balão, obtido no implante ou na pós-dilatação, e o diâmetro de referência do vaso pré-procedimento. Os pacientes foram categorizados em dois grupos: relação balão/artéria alta (≥ 1,15) e relação balão/artéria baixa (< 1,15). Resultados: Foram incluídos 86 pacientes, nos grupos relação balão/artéria baixa (n = 47/48 lesões) ou relação balão/artéria alta (n = 39/48 lesões). As características clínicas, angiográficas e do procedimento não diferiram entre os grupos, à exceção do diâmetro de referência dos vasos (2,73 ± 0,45 mm vs. 2,97 ± 0,40 mm; p = 0,01). Aos 12 meses, observou-se semelhante perda tardia intra-stent (0,59 ± 0,32 mm vs. 0,62 ± ...


Background: Intimal hyperplasia volume is correlated to arterial injury after bare-metal stenting. However, little is known about the impact of arterial injury on the inflammatory/ proliferative response with drug-eluting stents. We investigated the impact of arterial injury, evaluated by the balloon/artery ratio, on neointimal hyperplasia volume obstruction, evaluated by intravascular ultrasound, 12 months after zotarolimus-eluting stent implantation. Methods: Balloon/ artery ratio was defined as the ratio of the maximum balloon diameter, using the maximal implantation or post-dilatation pressure, and the reference diameter of the vessel obtained before the procedure. Patients were divided into two groups: high balloon/artery ratio (≥ 1.15) and low balloon/artery ratio (< 1.15). Results: A total of 86 patients were included in the low balloon/artery ratio group (n = 47/48 lesions) or high balloon/artery ratio (n = 39/48 lesions). The clinical, angiographic and procedurerelated characteristics were not different between groups, except for the vessel reference diameter (2.73 ± 0.45 mm vs. 2.97 ± 0.40 mm; p = 0.01). At 12 months, similar in-stent late loss was observed (0.59 ± 0.32 mm vs. 0.62 ± 0.42 mm; p = 0.92), as well as binary restenosis (4.2% in both cohorts; p > 0.99). Instent neointimal hyperplasia volume obstruction (15.2 ± 14.3% vs. 12.5 ± 10.1%; p = 0.62) showed no difference between groups. No correlation was observed between balloon/artery ratio ...

4.
Rev. bras. cardiol. invasiva ; 21(2): 109-114, abr.-jun. 2013. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-681942

ABSTRACT

INTRODUÇÃO: A hipertensão arterial sistêmica afeta mais de 1,2 milhão de pessoas no mundo. Apenas 35% dos pacientes hipertensos têm valores de pressão arterial controlados. Recentemente a denervação simpática renal (DSR) tem demonstrado diminuir significativamente os valores de pressão arterial nos pacientes com hipertensão arterial sistêmica resistente. MÉTODOS: Estudo prospectivo, de braço único, observacional, multicêntrico, incluindo pacientes consecutivos submetidos a DSR. O objetivo primário foi avaliar os níveis da pressão arterial sistólica aos 30 dias de seguimento. O objetivo secundário foi determinar a ocorrência de qualquer evento adverso relacionado com o procedimento. RESULTADOS: Foram incluídos os primeiros 20 pacientes submetidos a DSR. A média de pressão arterial antes do procedimento foi de 171,6/93,2 ± 15,5/11,3 mmHg, com média de uso de 4,1 ± 1,5 fármacos anti-hipertensivos por paciente. A taxa de sucesso foi de 95%, tendo sido aplicadas 11,1 ± 1,9 ablações por paciente. Foi observada diminuição média de 29 ± 21 mmHg (P = 0,009) na pressão arterial sistólica 30 dias após o procedimento. Não houve complicação associada ao procedimento. CONCLUSÕES: A DSR por cateter em pacientes da prática clínica diária diminuiu significativamente os valores de pressão arterial. Em nossa experiência, a DSR demonstrou ser factível e segura.


BACKGROUND: Systemic arterial hypertension affects over 1.2 million people worldwide. Only 35% of hypertensive patients have controlled blood pressure levels. Renal sympathetic denervation (RSD) has shown to significantly decrease blood pressure levels in patients with resistant systemic hypertension. METHODS: Prospective, single arm, observational, multicenter study including consecutive patients undergoing RSD. The primary endpoint was to assess systolic blood pressure levels at the 30-day follow-up. The secondary endpoint was to determine the presence of procedure-related adverse events. RESULTS: The first 20 patients undergoing RSD were included. The average blood pressure prior the procedure was 171.6/93.2 ± 15.5/ 11.3 mmHg, with the use of 4.1 ± 1.5 antihypertensive drugs per patient. Success rate was 95%, and 11.1 ± 1.9 ablations were performed per patient. A systolic blood pressure decrease of 29 ± 21 mmHg (P = 0.009) was observed 30 days after the procedure. There were no procedure-related complications. CONCLUSIONS: Catheter-based RSD in daily clinical practice patients significantly decreased blood pressure levels. In our experience, RSD proved to be feasible and safe.


Subject(s)
Humans , Male , Female , Catheters , Hypertension/complications , Hypertension/diagnosis , Kidney/physiopathology , Sympathectomy/methods , Sympathectomy , Prospective Studies , Acute Coronary Syndrome/complications , Acute Coronary Syndrome/mortality
5.
Rev. bras. cardiol. invasiva ; 19(3): 292-297, set. 2011. tab, graf
Article in Portuguese | LILACS, SES-SP | ID: lil-607266

ABSTRACT

Introdução: A expansão radial e a sustentação da parede do vaso pelos stents melhoraram os resultados da angioplastia coronária por balão. Entre as características dos stents mais contemporâneos destacam-se a redução da espessura de suas hastes e plataformas com novos desenhos, mas não está claro se essas modificações podem resultar em próteses de menor força radial e suscetíveis a recolhimento elástico, especialmente em evoluções muito tardias. Este estudo teve como objetivo investigar se ocorre recolhimento elástico tardio em duas gerações de stents farmacológicos (SFs) em avaliação por ultrassom intracoronário (USIC) seriado a longo prazo. Métodos: O estudo avaliou 25 pacientes com lesões coronárias únicas, de novo, tratados com SFs (12 CypherTM e 13 BioMatrixTM) e submetidos a USIC pós-procedimento e 4-6 meses e 4-5 anos após o implante. Foram comparados os volumes dos stents no período compreendido entre o procedimento índice e os reestudos de médio e longo prazos. O recolhimento elástico do stent foi definido como diminuição > 10% do volume índice do stent. Resultados: A maioria dos pacientes era do sexo masculino (52%), com média de idade de 58,8 ± 7,6 anos, e 28% eram diabéticos. O volume do stent índice, objetivo primário deste estudo, foi de 7,7 ± 1,5 mm3/mm no pós-procedimento, de 7,7 ± 2,1 mm3/mm aos 4-6 meses, e de 7,8 ± 1,6 mm3/mm aos 4-5 anos, com variação tardia de -0,02 ± 1,6 mm3/mm (P = 0,97). A variação a longo prazo do volume do stent índice foi de 0,13 ± 1,8 mm3/mm (1,7%) para o stent CypherTM e de -0,05 ± 1,3 mm3/mm (-0,6%) para o stent BioMatrixTM (P = 0,78). Conclusões: A avaliação invasiva seriada por meio do USIC mostrou que SFs de aço inoxidável, de diferentes gerações, não demonstraram evidência de recolhimento elástico a longo prazo.


BACKGROUND: Radial expansion and vessel wall scaffolding properties of stainless steel stents have improved the outcomes of coronary balloon angioplasty. Thinner struts and new platform designs are characteristic of more contemporaneous stents, but it is not clear whether these changes may result in devices with less radial strength, susceptible to elastic recoil, especially in the very late follow-up. This study was aimed at assessing late stent recoil in two generations of drug-eluting stents (DES) using serial intravascular ultrasound (IVUS) analysis. METHODS: Twenty-five patients with single de novo coronary lesions, treated with DES (12 CypherTM and 13 BioMatrixTM), were included and serial IVUS analysis was performed after stent implantation and at 4-6-months and 4-5 years of follow-up. Stent volume index was compared between the procedure and the mid and long-term follow-ups. Stent recoil was defined as a decrease > 10% of the stent volume index. RESULTS: Most of the patients were male (52%), with mean age of 58.8 ± 7.6 years, and 28% were diabetic. Stent volume index, the primary objective of this study, was 7.7 ± 1.5 mm³/mm post-procedure, 7.7 ± 2.1 mm³/mm at 4-6 months and 7.8 ± 1.6 mm³/mm at 4-5 years, with a delta of -0.02 ± 1.6 mm³/mm (P = 0.97). The long-term delta stent volume index was 0.13 ± 1.8 mm³/mm (1.7%) for the CypherTM stent and -0.05 ± 1.3 mm³/mm (-0.6%) for the BioMatrixTM stent (P = 0.78). CONCLUSIONS: Serial IVUS analysis showed that stainless steel DES of different generations did not show evidence of long-term elastic recoil.


Subject(s)
Humans , Male , Female , Middle Aged , Angioplasty/methods , Angioplasty , Drug-Eluting Stents , Ultrasonics , Prospective Studies , Risk Factors
6.
Rev. bras. cardiol. invasiva ; 19(2): 122-130, jul. 2011. tab, graf
Article in Portuguese | LILACS, SES-SP | ID: lil-595224

ABSTRACT

Introdução: Embora os stents farmacológicos tenham reduzido acentuadamente a reestenose e a necessidade de novas revascularizações na maioria dos cenários clínicos e angiográficos, o benefício desses dispositivos no tratamento de lesões em enxertos de veia safena (EVS) ainda precisa ser definido. O objetivo deste estudo foi comparar a incidência de eventos cardíacos adversos maiores (ECAM) entre stents farmacológicos e stents não-farmacológicos em lesões em EVS em pacientes não-selecionados. Métodos: Foram incluídos pacientes tratados em dois hospitais terciáriosentre maio de 2006 e janeiro de 2009. O objetivo primário foi comparar a incidência de ECAM entre stents farmacológicos e stents não-farmacológicos durante a hospitalizaçãoe no seguimento a longo prazo. Resultados: No total, foram incluídos, consecutivamente, 308 pacientes, divididos de acordo com o tipo de stent implantado (209 com stents farmacológicos e 99 com stents não-farmacológicos). A média de idade do grupo foi de 68 anos e a dos EVS, de 10,9 anos. Na fase intra-hospitalar, houve tendência para maior incidência de ECAM no grupo que recebeu stents farmacológicos (12% vs. 5,1%; P = 0,06). Até 24 meses, a incidência de ECAM foi equivalente nos dois grupos (17,2% nogrupo stents farmacológicos vs. 18,2% no grupo stents não-farmacológicos; P = 0,87). Trombose do stent definitiva/provável foi semelhante em ambos os grupos (2,3% no grupo stents farmacológicos vs. 2% no grupo stentsnão-farmacológicos; P = 0,94). Conclusões: Nesta série de pacientes complexos do mundo real, não houve preocupação com a segurança a longo prazo relacionada ao uso de stents farmacológicos no tratamento de lesões em EVS, com incidências similares de morte cardíaca/infarto do miocárdio/trombose do stent em ambos os grupos.


Background: Although drug-eluting stents have markedly reduced restenosis and the need for repeat lesion revascularization in the vast majority of clinical and angiographic scenarios, the benefit of these devices for the treatment of saphenous-vein graft (SVG) lesions is yet to be defined. The aim of our study was to compare the rate of major adverse clinical events (MACE) between drug-eluting stentsand bare-metal stents in SVG lesions in non-selected patients. Methods: Patients treated in two tertiary hospitals betweenMay 2006 and January 2009 were included. The primary objective was to compare the incidence of MACE betweendrug-eluting stents and bare-metal stents during hospitalization and in the long-term follow-up. Results: Overall, 308 patients were consecutively enrolled and divided according to the type of stent deployed (209 with drug-eluting stents and 99 with bare-metal stents). Mean age was 68 years and SVG mean age was 10.9 years. In the in-hospital phase there was a trend towards higher MACE in the drug-eluting stents group (12% vs. 5.1%; P = 0.06). The incidence of MACE in up to 24 months was equivalent between groups (17.2%for the drug-eluting stents group vs. 18.2% for the baremetal stents group; P = 0.87). Definite/probable stent thrombosis was similar in both groups (2.3% for the drug-eluting stents group vs. 2% for bare-metal stents group; P = 0.94). Conclusions: In this real world series of complex patients there was no long-term safety concerns related to the use of drug-eluting stents in the treatment of SVG lesions, with similar rates of cardiac death/myocardial infarction/stent thrombosis in both groups.


Subject(s)
Humans , Male , Female , Aged , Drug-Eluting Stents , Stents , Saphenous Vein/surgery , Saphenous Vein/injuries , Myocardial Revascularization/methods , Myocardial Revascularization , Thrombosis/complications
7.
Rev. bras. cardiol. invasiva ; 18(4): 379-386, dez. 2010. tab, ilus, graf
Article in Portuguese | LILACS | ID: lil-582202

ABSTRACT

Introdução: A reestenose intrastent (RIS), resultante da excessiva resposta reparadora neointimal após o implante da prótese, é uma das principais limitações da intervenção coronária percutânea. A despeito da eficácia dos stents farmacológicos (SF) de primeira geração no tratamento da RIS, questões relacionadas à segurança e ao perfil de flexibilidade/navegabilidade dessas próteses estimularam o desenvolvimento de novas gerações de SF. O novo SF Firebird TM (Microport Co. Ltd., Xangai, China) combina uma plataforma de aço inoxidável (316 L) de hastes finas (0,0040 polegada), um potente agente antiproliferativo (sirolimus, na dose de 9 ug/mm2) e um revestimento que inclui três camadas de polímero durável, que controla a liberação do fármaco. Apesar de ser um dos SF mais utilizados na China, pouco se conhece sobre seu desempenho, sobretudo em subgrupos de maior complexidade. Método: Entre fevereiro e dezembro de 2009, pacientes portadores de lesão reestenótica única, de stents não-farmacológicos, foram submetidos a intervenão coronária percutânea com implante de stent Firebird TM. Avaliação com angiografia ultrassom intracoronário (USIC) foi programada para todos os pacientes...


BACKGROUND: In-stent restenosis (ISR), resulting from excessive neointimal hyperplasia, is a major limitation of percutaneous coronary intervention. Despite the efficacy of first generation drug-eluting stents (DES) in the treatment of ISR, issues related to the safety and flexibility/navigability profile have encouraged the development of new generations of DES. The new FirebirdTM DES (Microport Co. Ltd., Shanghai, China) combines a stainless steel platform (L316) of fine struts (0,0040'), a powerful anti-proliferative agent (sirolimus, at a dose of 9 µg/mm²) and a coating that includes three layers of a durable polymer, which controls drug release. Though it is a most used DES in China, little is known about its performance, particularly in subgroups of greater complexity. METHOD: Between February and December 2009, patients with single bare metal stent restenotic lesions, were submitted to percutaneous coronary intervention with FirebirdTM stent implantation. Angiography and intravascular ultrasound (IVUS) were scheduled for all patients at 12 months of follow-up. The primary end-point was late loss and the percentage of in-stent volumetric obstruction at 12 months. RESULTS: Twenty-five patients with mean age of 56.8 ± 7.7 years were included, of which 80% were males and 40% diabetics. The anterior descending artery was the most frequently treated vessel (44%) and most lesions had a diffuse/proliferative pattern (64%). At 12 months, late luminal loss was 0.3 ± 0.24 mm, and no case of binary restenosis was identified. IVUS percent volumetric obstruction was 2.6 ± 1.9%. CONCLUSION: In this single center study, the new FirebirdTM DES showed favorable angiographic and IVUS results for the treatment of bare metal ISR at the one year follow-up.


Subject(s)
Humans , Male , Female , Middle Aged , Angioplasty, Balloon, Coronary/methods , Angioplasty, Balloon, Coronary , Coronary Restenosis/surgery , Sirolimus/administration & dosage , Drug-Eluting Stents/trends , Drug-Eluting Stents , Angiography/methods , Angiography
8.
Rev. bras. cardiol. invasiva ; 18(4): 400-406, dez. 2010. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-582205

ABSTRACT

INTRODUÇÃO: Os stents com liberação de fármacos antiproliferativos (SF) têm demonstrado sua eficácia nos mais variados cenários. Entretanto, preocupações recentes com a maior ocorrência de trombose muito tardia com a primeira geração de SF, possivelmente associda a reendotelização retardada ou incompleta, impulsionaram o desenvolvimento de dispositivos mais eficazes e seguros. Método: Estudo retrospectivo, de centro único, incluindo pacientes submetidos a intervenção coronária percutânea entre janeiro de 2006 e dezembro de 2008, tratados com SF com liberação de everolimus (everolimus-eluting stent - EES) (Xience V TM/Promus TM) e com SF com liberação de zotarolimus (zotarolimus-eluting stent - ZES) (Endeavor TM). O objetivo principal foi comparar a taxa de eventos cardíacos maiores no seguimento de 12 meses entre os pacientes dos grupos EES e ZES. Resultados: No total, 198 pacientes com 266 lesões foram incluídos nesta análise. A média de idade foi de 60 + - 10 anos e 39 por cento tinham diabetes melito, sem diferenças entre os grupos. O diâmetro de referência (2,3 + - 0,5 mm vs. 2,38 + - 0,2 mm; P=0,14) e a extensão da lesão (16,3 + - 9,4 mm vs. 16,1 + - 11,3 mm; P = 0,89) também não diferiram entre os grupos. Após 12 meses de seguimento, a taxa de eventos...


BACKGROUND: The use of drug-eluting stents (DES) has proven to be effective in different angiographic scenarios. However, recent concerns with the occurrence of very late stent thrombosis with the first DES generation, probably related to delayed or incomplete endothelization, have led to the development of new safer and more effective devices. METHOD: Retrospective, single center study, including patients undergoing percutaneous coronary intervention between January 2006 and December 2008, treated with everolimuseluting stent (EES) (Xience V TM/PromusTM) and zotarolimuseluting stent (ZES) (EndeavorTM). Our objective was to compare the rates of major adverse cardiac events between EES and ZES patients after 12 months of follow-up. RESULTS: Overall, 198 patients with 266 lesions were included in the study. Mean age was 60 ± 10 years and 39% had diabetes mellitus, without significant differences between groups. The reference diameter (2.3 ± 0.5 mm vs. 2.38 ± 0.2 mm; P = 0.14), as well as lesion length (16.3 ± 9.4 mm vs. 16.1 ± 11.3 mm; P = 0.89), were also not significantly different between groups. After 12 months of follow-up, the rate of major adverse cardiac events was 8.16% in the EES group vs. 8% in the ZES group (P = 0.96), with a global rate of target-lesion revascularization of 2% (1% EES and 3% ZES; P = 0.32). There were no cases of definite stent thrombosis. CONCLUSION: In this study of non-selected patients, the rates of major adverse cardiac events were similar between patients treated in the EES and ZES groups, with low target-lesion revascularization rates and excellent safety profile after 12 months of follow-up.


Subject(s)
Humans , Male , Female , Middle Aged , Angioplasty, Balloon, Coronary/methods , Angioplasty, Balloon, Coronary , Coronary Restenosis/surgery , Myocardial Revascularization/methods , Myocardial Revascularization , Drug-Eluting Stents , Retrospective Studies , Risk Factors